Medical Stainless Tubing

Hypodermic tubing is commonly used as the medium for introducing medicine or drugs under skin. Either as a method of injection or removal, hypodermic tubing allows for the rapid delivery of fluids. Ως αποτέλεσμα, this type of stainless steel tubing is usually formed into hypodermic needles for medical applications. It is a slender, hollow, cylindrical length of stainless steel, typically SUS 316/SUS316L or SUS304 grade or 1.4301,1.4401,1.4404, with a puncturing point made at one end to form a needle.

If any questions,καλώς ήρθατε να επικοινωνήσετε sales@grandsteeltube.com

  • Περιγραφή: __________
  • Detailed Introduction
  • Hypodermic Tube Size Range
  • Εξέταση

Hypodermic tubing is differentiated from other types of tubing by its own set of gauge sizes. For example, fractional tubing is measured by outside diameter and wall thickness, using common fraction sizes like 1/4outside diameter combined with a .035″ πάχος τοιχώματος. Hypodermic tubing comes in thin, regular and heavy wall varieties. Hypodermic tubing may be offered in 6″, 12″, 24″ or 36lengths. Όμως, hypodermic tubing, or needle tubing, is categorized by gauges, which are determined by the outside diameter and the inside diameter of the tube. Hypodermic tubing can range from0.005to 0.259outside diameter and 0.002to 0.239inside diameter. Hypodermic tubing gauges are generally found numbered between 3 και 35, the smaller the number, the larger the diameters. For medical applications, the largest usable gauge size is 7, while the smallest usable gauge size is 33. Hypodermic tubing gauges are rooted in the Birmingham Gage, which is otherwise known as Stub’s Iron Wire Gage and also measures the thicknesses of pipes. Hypodermic tubing manufacturers should have gauge size charts available to assist in deciding which type of hypodermic tubing is needed for a specific application.

Εάν έχετε οποιεσδήποτε ερωτήσεις,είστε περισσότερο από ευπρόσδεκτοι να επικοινωνήσετε sales@grandsteeltube.com

In terms of needle applications, there are a variety of diameters of hypodermic tubing that work best for certain requirements. Για παράδειγμα, large diameter hypodermic tubing are used for blood donation because the wideness of the needle allows for the removal of blood at a much quicker pace than would be allowed by an average or small diameter hypodermic tube. Small diameter hypodermic tubing, on the other hand, should not be used for blood donations because the small size of the needle will rupture the red blood cells and make the blood unable to be utilized by recipients. In addition to needle applications, hypodermic tubing is also utilized for spacers, hypodermic guide wires, cannulas and hypodermic capillary tubing in the medical, mechanical, electronic, chemical and aeronautical industries.

Hypodermic tubing is differentiated from other types of tubing by its own set of gauge sizes. For example, fractional tubing is measured by outside diameter and wall thickness, using common fraction sizes like 1/4″ outside diameter combined with a .035″ wall thickness. Hypodermic tubing comes in thin, regular and heavy wall varieties. Hypodermic tubing may be offered in 6″, 12, 24″ or 36″ lengths. Όμως, hypodermic tubing, or needle tubing, is categorized by gauges, which are determined by the outside diameter and the inside diameter of the tube. Hypodermic tubing can range from0.005″ to 0.259″ outside diameter and 0.002″ to 0.239″ inside diameter. Hypodermic tubing gauges are generally found numbered between 3 και 35, the smaller the number, the larger the diameters. For medical applications, the largest usable gauge size is 7, while the smallest usable gauge size is 33. Hypodermic tubing gauges are rooted in the Birmingham Gage, which is otherwise known as Stub’s Iron Wire Gage and also measures the thicknesses of pipes. Hypodermic tubing manufacturers should have gauge size charts available to assist in deciding which type of hypodermic tubing is needed for a specific application.

Βαθμολογώ SUS304/304L,SUS316/316L,1.4301,1.4306,1.4401,1.4404
Πρότυπο A269,EN10217-7
ΥΔ 0.30mm-3.40mm
WT 0.05χιλ.-0.39χιλ.
Μήκος Depending on your requirement.from 10mm to hundreds of meters
Προθεσμία παράδοσης FOB Shanghai ή CIF το λιμάνι προορισμού σας.
Χρόνος παράδοσης 10~30 days ,ανάλογα με την ποσότητα παραγγελίας
Τεχνική Welded or welded & Επανασχεδιάζεται
Πακέτο Ξύλινο κουτί,ή ως διαπραγμάτευση
Πληρωμή Τ/Τ 30% Προκαταβολή+70% πριν από την αποστολή.

Εάν έχετε οποιεσδήποτε ερωτήσεις,είστε περισσότερο από ευπρόσδεκτοι να επικοινωνήσετε sales@grandsteeltube.com

Hypodermic Tube Size Range

 

Gauge Outside Diameter Tolerance mm Regular Wall Thickness (RWT) χιλ. Thin Wall Thickness mm Extra Thin Wall Thicknessmm Ultra Thin Wall Thickness mm
30 0.304 – 0.317 0.064 – 0.089
29 o.330 – 0.342 0.064 – 0.089
28 0.355 – 0.368 0.076 – 0.102
27 0.406 – 0.419 0.089 – 0.115 0.064 – 0.089
26 0.457 – 0.469 0.089 – 0.114
25 0.508 – 0.520 0.115 – 0.140 0.089 – 0.114
24 0.558 – 0.571 0.114 – 0.140 0.089 – 0.114 0.051 – 0.102
23 0.635 – 0.647 0.140 – 0.165 0.089 – 0.114 0.051 – 0.102
22 0.711 – 0.723 0.140 – 0.165 0.096 – 0.121 0.077 – 0.102 0.051 – 0.102
21 0.812 – 0.825 0.140 – 0.165 0.102 – 0.127 0.051 – 0.102
20 0.901 – 0.914 0.108 – 0.165 0.108 – 0.134
19 1.054 – 1.079 0.166 – 0.216 0.102 – 0.140 0.070 – 0.108
18 1.257 – 1.282 0.191 – 0.241 0.127 – 0.165 0.083 – 0.121 0.051 – 0.102
17 1.460 – 1.485 0.177 – 0.229 0.115 – 0.152 0.083 – 0.127 0.057 – 0.102
16 1.638 – 1.663 0.204 – 0.254 0.127 – 0.165 0.096 – 0.133 0.070 – 0.121
15 1.816 – 1.841 0.204 – 0.254 0.127 – 0.165 0.096 – 0.134 0.070 – 0.121
14 2.082 – 2.133 0.216 – 0.292 0.165 – 0.229 0.114 – 0.165 0.076 – 0.134
13 2.387 – 2.438 0.267 – 0.343 0.191 – 0.267
12 2.743 – 2.749 0.267 – 0.321
11 3.023 – 3.073 0.293 – 0.368 0.216 – 0.292
10 3.378 – 3.429 0.318 – 0.394 0.216 – 0.292

Εάν έχετε οποιεσδήποτε ερωτήσεις,είστε περισσότερο από ευπρόσδεκτοι να επικοινωνήσετε sales@grandsteeltube.com